Description
Specification # 36F551-738
Baldor Reliance motors have long been a trusted tool for the farm. Whether you’re handling wheat, barley, soybeans, corn, or another crop, these industrial crop dryer units are ideal for drying and storage use. These motors are also used for vane axial fans, such as those found in tunnel ventilations, garage exhausts, HVAC systems, and clean rooms. Features include:
- 3/4” longer shaft - keyed, drilled & tapped with internal ¼-20 tap 1”
- Internal thermostats for temperature monitoring
- TEAO (enclosed) motors with sealed bearings, seals, and slingers to stop moisture
Specs
Catalog NumberUCM713
EnclosureODP
Frame184TZ
Frame MaterialSteel
Frequency60.00 Hz
Haz Area Class and GroupNone
Haz Area DivisionNot Applicable
Motor Letter TypeThree Phase
Output @ Frequency10.000 HP @ 60 HZ
Phase3
Synchronous Speed @ Frequency3600 RPM @ 60 HZ
Voltage @ Frequency208.0 V @ 60 HZ
230.0 V @ 60 HZ
460.0 V @ 60 HZ Agency ApprovalsUR
CSA Ambient Temperature40 °C Auxillary BoxNo Auxillary Box Auxillary Box Lead TerminationNone Base IndicatorRigid Bearing Grease TypePolyrex EM (-20F +300F) BlowerNone Current @ Voltage12.000 A @ 460.0 V
24.000 A @ 230.0 V
25.000 A @ 208.0 V Design CodeB Drip CoverNo Drip Cover Duty RatingCONT Efficiency @ 100% Load84.0 % Electrically Isolated BearingNot Electrically Isolated Feedback DeviceNO FEEDBACK Front Face CodeStandard Front Shaft IndicatorNone Heater IndicatorNo Heater High Voltage Full Load Amps12.0 a Insulation ClassF Inverter CodeNot Inverter KVA CodeJ Lifting LugsStandard Lifting Lugs Locked Bearing IndicatorLocked Bearing Motor Lead ExitPipe Or Pipe Adaptor Motor Lead Quantity/Wire Size9 @ 14 AWG Motor Lead TerminationFlying Leads Motor StandardsNEMA Motor Type3646M Mounting ArrangementF1 Number of Poles2 Overall Length16.87 IN Power Factor92 Product FamilyGeneral Purpose Product TypeFARM DUTY Pulley End Bearing TypeBall Pulley Face CodeStandard Pulley Shaft IndicatorTapped & Key Rodent ScreenNone Service Factor1.00 Shaft Diameter1.125 IN Shaft Extension LocationPulley End Shaft Ground IndicatorNo Shaft Grounding Shaft RotationReversible Shaft Slinger IndicatorNo Slinger Speed3450 rpm Speed CodeSingle Speed Starting MethodDirect on line Thermal Device - BearingNone Thermal Device - WindingNormally Closed Thermostat Vibration Sensor IndicatorNo Vibration Sensor Winding Thermal 1None Winding Thermal 2None
230.0 V @ 60 HZ
460.0 V @ 60 HZ Agency ApprovalsUR
CSA Ambient Temperature40 °C Auxillary BoxNo Auxillary Box Auxillary Box Lead TerminationNone Base IndicatorRigid Bearing Grease TypePolyrex EM (-20F +300F) BlowerNone Current @ Voltage12.000 A @ 460.0 V
24.000 A @ 230.0 V
25.000 A @ 208.0 V Design CodeB Drip CoverNo Drip Cover Duty RatingCONT Efficiency @ 100% Load84.0 % Electrically Isolated BearingNot Electrically Isolated Feedback DeviceNO FEEDBACK Front Face CodeStandard Front Shaft IndicatorNone Heater IndicatorNo Heater High Voltage Full Load Amps12.0 a Insulation ClassF Inverter CodeNot Inverter KVA CodeJ Lifting LugsStandard Lifting Lugs Locked Bearing IndicatorLocked Bearing Motor Lead ExitPipe Or Pipe Adaptor Motor Lead Quantity/Wire Size9 @ 14 AWG Motor Lead TerminationFlying Leads Motor StandardsNEMA Motor Type3646M Mounting ArrangementF1 Number of Poles2 Overall Length16.87 IN Power Factor92 Product FamilyGeneral Purpose Product TypeFARM DUTY Pulley End Bearing TypeBall Pulley Face CodeStandard Pulley Shaft IndicatorTapped & Key Rodent ScreenNone Service Factor1.00 Shaft Diameter1.125 IN Shaft Extension LocationPulley End Shaft Ground IndicatorNo Shaft Grounding Shaft RotationReversible Shaft Slinger IndicatorNo Slinger Speed3450 rpm Speed CodeSingle Speed Starting MethodDirect on line Thermal Device - BearingNone Thermal Device - WindingNormally Closed Thermostat Vibration Sensor IndicatorNo Vibration Sensor Winding Thermal 1None Winding Thermal 2None
Nameplate
CAT.NO. | UCM713 | |||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SPEC. | 36F551-738 | |||||||||||||||||||||||||||||
HP | 7.5-10 AIR OVER | |||||||||||||||||||||||||||||
VOLTS | 208-230/460 | |||||||||||||||||||||||||||||
AMP | 25-24/12 | |||||||||||||||||||||||||||||
RPM | 3450 | |||||||||||||||||||||||||||||
FRAME | 184TZ | HZ | 60 | PH | 3 | |||||||||||||||||||||||||
SER.F. | 1.00 | CODE | J | DES | B | CL | F | |||||||||||||||||||||||
NEMA-NOM-EFF | 84 | PF | 92 | |||||||||||||||||||||||||||
RATING | 40C AMB-CONT | |||||||||||||||||||||||||||||
CC | ||||||||||||||||||||||||||||||
DE | 6206 | ODE | 6205 | |||||||||||||||||||||||||||
ENCL | OPEN | SN | ||||||||||||||||||||||||||||
NP1279L |
CAT.NO. | UCM713 | |||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SPEC. | 36F551-738 | |||||||||||||||||||||||||||||
HP | 7.5-10 AIR OVER | |||||||||||||||||||||||||||||
VOLTS | 208-230/460 | |||||||||||||||||||||||||||||
AMP | 25-24/12 | |||||||||||||||||||||||||||||
RPM | 3450 | |||||||||||||||||||||||||||||
FRAME | 184TZ | HZ | 60 | PH | 3 | |||||||||||||||||||||||||
SER.F. | 1.00 | CODE | J | DES | B | CL | F | |||||||||||||||||||||||
NEMA-NOM-EFF | 84 | PF | 92 | |||||||||||||||||||||||||||
RATING | 40C AMB-CONT | |||||||||||||||||||||||||||||
CC | ||||||||||||||||||||||||||||||
DE | 6206 | ODE | 6205 | |||||||||||||||||||||||||||
ENCL | OPEN | SN | ||||||||||||||||||||||||||||
NP1263L |