ZDWNM3611T Baldor Motor 3HP 1750RPM 184TC TENV 230/460 Volt 3 Phase 36J562S952Z1
- Description
- SPECS
- Nameplate
ZDWNM3611T: Baldor, 3HP, 1750RPM, 3PH, 184TC, TENV
Baldor Vector Drive Washdown Totally Enclosed Non Ventilated Motors used for Material handling, packaging equipment in food processing and other wet environments. For adjustable speed applications requiring full torque from zero to base speed.
Baldor Motor Parts, Diagrams and Specs Available!
Specification # 36J562Y533Z2
Catalog Number ZDWNM3611T
Enclosure TENV
Frame 184TC
Frame Material Steel
Frequency 60.00 Hz
Haz Area Class and Group None
Haz Area Division Not Applicable
Motor Letter Type Three Phase
Output @ Frequency 3.000 HP @ 60 HZ
Phase 3
Synchronous Speed @ Frequency 1800 RPM @ 60 HZ
Voltage @ Frequency 230.0 V @ 60 HZ
460.0 V @ 60 HZ
Agency Approvals UR
CSA
Ambient Temperature 40 °C
Auxillary Box No Auxillary Box
Auxillary Box Lead Termination None
Base Indicator Rigid
Bearing Grease Type Polyrex EM (-20F +300F)
Blower None
Current @ Voltage 4.100 A @ 460.0 V
8.200 A @ 230.0 V
Design Code B
Drip Cover No Drip Cover
Duty Rating CONT
Efficiency @ 100% Load 89.5 %
Electrically Isolated Bearing Not Electrically Isolated
Feedback Device ENCODER
Front Face Code Encoder/Feedback Device
Front Shaft Indicator None
Heater Indicator No Heater
High Voltage Full Load Amps 4.1 a
Insulation Class H
Inverter Code Inverter Duty
KVA Code K
Lifting Lugs No Lifting Lugs
Locked Bearing Indicator Locked Bearing
Max Speed 6000 rpm
Motor Lead Exit Ko Box
Motor Lead Quantity/Wire Size 9 @ 16 AWG
Motor Lead Termination Flying Leads
Motor Standards NEMA
Motor Type 3640M
Mounting Arrangement F1
Number of Poles 4
Overall Length 19.27 IN
Power Factor 78
Product Family Wash Down
Pulley End Bearing Type Ball
Pulley Face Code C-Face
Pulley Shaft Indicator Standard
Rodent Screen None
RoHS Status ROHS NON-COMPLIANT
Service Factor 1.00
Shaft Diameter 1.125 IN
Shaft Extension Location Pulley End
Shaft Ground Indicator No Shaft Grounding
Shaft Rotation Reversible
Shaft Slinger Indicator Shaft Slinger
Speed 1760 rpm
Speed Code Single Speed
Starting Method Direct on line
Thermal Device - Bearing None
Thermal Device - Winding Normally Closed Thermostat
Vibration Sensor Indicator No Vibration Sensor
Winding Thermal 1 None
Winding Thermal 2 None
CAT NO | ZDWNM3611T | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SPEC. | 36J562S952Z1 | |||||||||||||||||||||||||||||||||
FRAME | 184TC | HP | 3 TE | |||||||||||||||||||||||||||||||
VOLTS | 230/460 | |||||||||||||||||||||||||||||||||
MAG CUR | 4.2/2.1 | FLA | 8.2/4.1 | |||||||||||||||||||||||||||||||
RPM | 1760 | RPM MAX | 6000 | |||||||||||||||||||||||||||||||
HZ | 60 | PH | 3 | CLASS | H | |||||||||||||||||||||||||||||
SER.F. | 1.00 | DES | B | SL HZ | 1.4 | |||||||||||||||||||||||||||||
NEMA-NOM-EFF | 89.5 | WK2 | 0.372 | |||||||||||||||||||||||||||||||
BLWR V | PH | HZ | A | |||||||||||||||||||||||||||||||
RATING | 40C AMB-CONT | |||||||||||||||||||||||||||||||||
DE BRG | 6206 | ODE BRG | 6205 | |||||||||||||||||||||||||||||||
CC | 010A | SER.NO | ||||||||||||||||||||||||||||||||
NP1609L |