Specification # 37E767Z89
Baldor Reliance motors have long been a trusted tool for the farm. Whether you’re handling wheat, barley, soybeans, corn, or another crop, these industrial crop dryer units are ideal for drying and storage use. These electric motors are also used for vane axial fans, such as those found in tunnel ventilations, garage exhausts, HVAC systems, and clean rooms. Features include:
- 3/4” longer shaft - keyed, drilled & tapped with internal ¼-20 tap 1”
- Internal thermostats for temperature monitoring
- TEAO (enclosed) motors with sealed bearings, seals, and slingers to stop moisture
Square One Electric is an authorized Delaware Baldor distributor with access to nationwide warehouses. Contact Us if you need more information, replacement motor parts, or connection diagrams.
Specs
Catalog NumberUCL7510
EnclosureOPAO
Frame215Z
Frame MaterialSteel
Frequency60.00 Hz
Haz Area Class and GroupNone
Haz Area DivisionNot Applicable
Motor Letter TypeCap Start, Induction Run
Output @ Frequency7.500 HP @ 60 HZ
10.500 HP @ 60 HZ Phase1 Synchronous Speed @ Frequency3600 RPM @ 60 HZ Voltage @ Frequency230.0 V @ 60 HZ Agency ApprovalsUR
CSA Ambient Temperature40 °C Auxillary BoxNo Auxillary Box Auxillary Box Lead TerminationNone Base IndicatorRigid Bearing Grease TypePolyrex EM (-20F +300F) BlowerNone Current @ Voltage37.000 A @ 230.0 V Design CodeL Drip CoverNo Drip Cover Duty RatingCONT Efficiency @ 100% Load81.0 % Electrically Isolated BearingNot Electrically Isolated Feedback DeviceNO FEEDBACK Front Face CodeStandard Front Shaft IndicatorNone Heater IndicatorNo Heater High Voltage Full Load Amps37.0 a Insulation ClassF Inverter CodeNot Inverter KVA CodeF Lifting LugsStandard Lifting Lugs Locked Bearing IndicatorLocked Bearing Motor Lead ExitPipe Or Pipe Adaptor Motor Lead Quantity/Wire Size2 @ 8 AWG, A PH Motor Lead TerminationFlying Leads Motor StandardsNEMA Motor Type3729L Mounting ArrangementF1 Number of Poles2 Overall Length17.44 IN Power Factor82 Product FamilyGeneral Purpose Product TypeFARM DUTY Pulley End Bearing TypeSealed Bearing Pulley Face CodeStandard Pulley Shaft IndicatorTapped & Key Rodent ScreenIncluded Service Factor1.00 Shaft Diameter1.125 IN Shaft Extension LocationPulley End Shaft Ground IndicatorNo Shaft Grounding Shaft RotationReversible Shaft Slinger IndicatorNo Slinger Speed3450 rpm Speed CodeSingle Speed Starting MethodDirect on line Thermal Device - BearingNone Thermal Device - WindingNormally Closed Thermostat Vibration Sensor IndicatorNo Vibration Sensor Winding Thermal 1None Winding Thermal 2None
10.500 HP @ 60 HZ Phase1 Synchronous Speed @ Frequency3600 RPM @ 60 HZ Voltage @ Frequency230.0 V @ 60 HZ Agency ApprovalsUR
CSA Ambient Temperature40 °C Auxillary BoxNo Auxillary Box Auxillary Box Lead TerminationNone Base IndicatorRigid Bearing Grease TypePolyrex EM (-20F +300F) BlowerNone Current @ Voltage37.000 A @ 230.0 V Design CodeL Drip CoverNo Drip Cover Duty RatingCONT Efficiency @ 100% Load81.0 % Electrically Isolated BearingNot Electrically Isolated Feedback DeviceNO FEEDBACK Front Face CodeStandard Front Shaft IndicatorNone Heater IndicatorNo Heater High Voltage Full Load Amps37.0 a Insulation ClassF Inverter CodeNot Inverter KVA CodeF Lifting LugsStandard Lifting Lugs Locked Bearing IndicatorLocked Bearing Motor Lead ExitPipe Or Pipe Adaptor Motor Lead Quantity/Wire Size2 @ 8 AWG, A PH Motor Lead TerminationFlying Leads Motor StandardsNEMA Motor Type3729L Mounting ArrangementF1 Number of Poles2 Overall Length17.44 IN Power Factor82 Product FamilyGeneral Purpose Product TypeFARM DUTY Pulley End Bearing TypeSealed Bearing Pulley Face CodeStandard Pulley Shaft IndicatorTapped & Key Rodent ScreenIncluded Service Factor1.00 Shaft Diameter1.125 IN Shaft Extension LocationPulley End Shaft Ground IndicatorNo Shaft Grounding Shaft RotationReversible Shaft Slinger IndicatorNo Slinger Speed3450 rpm Speed CodeSingle Speed Starting MethodDirect on line Thermal Device - BearingNone Thermal Device - WindingNormally Closed Thermostat Vibration Sensor IndicatorNo Vibration Sensor Winding Thermal 1None Winding Thermal 2None
Nameplate
| CAT.NO. | UCL7510 | |||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SPEC. | 37E767Z089G1 | |||||||||||||||||||||||||||||
| HP | 7.5-10.5 AIR OVER | |||||||||||||||||||||||||||||
| VOLTS | 230 | |||||||||||||||||||||||||||||
| AMP | 37-46 | |||||||||||||||||||||||||||||
| RPM | 3450 | |||||||||||||||||||||||||||||
| FRAME | 215Z | HZ | 60 | PH | 1 | |||||||||||||||||||||||||
| SER.F. | 1.00 | CODE | F | DES | L | CL | F | |||||||||||||||||||||||
| NEMA-NOM-EFF | 81 | PF | 82 | |||||||||||||||||||||||||||
| RATING | 40C AMB-CONT | |||||||||||||||||||||||||||||
| CC | ||||||||||||||||||||||||||||||
| DE | 6307 | ODE | 6206 | |||||||||||||||||||||||||||
| ENCL | OPAO | SN | ||||||||||||||||||||||||||||
| NP1279L | ||||||||||||||||||||||||||||||
| CAT.NO. | UCL7510 | |||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SPEC. | 37E767Z089G1 | |||||||||||||||||||||||||||||
| HP | 7.5-10.5 AIR OVER | |||||||||||||||||||||||||||||
| VOLTS | 230 | |||||||||||||||||||||||||||||
| AMP | 37-46 | |||||||||||||||||||||||||||||
| RPM | 3450 | |||||||||||||||||||||||||||||
| FRAME | 215Z | HZ | 60 | PH | 1 | |||||||||||||||||||||||||
| SER.F. | 1.00 | CODE | F | DES | L | CL | F | |||||||||||||||||||||||
| NEMA-NOM-EFF | 81 | PF | 82 | |||||||||||||||||||||||||||
| RATING | 40C AMB-CONT | |||||||||||||||||||||||||||||
| CC | ||||||||||||||||||||||||||||||
| DE | 6307 | ODE | 6206 | |||||||||||||||||||||||||||
| ENCL | OPAO | SN | ||||||||||||||||||||||||||||
| NP1263L | ||||||||||||||||||||||||||||||