CXM05122 Baldor Motor 1HP 3450RPM 56C XPFC 208-230/460 Volt 3 Phase 35-0000-0881
SKU:
CXM05122
Regular price
Regular price
Sale
Sale price
- Description
- Specs
- Nameplate
Description
REPLACES CM7013 / CEM7013
Baldor's Explosion-proof motors are ideal for a wide variety of applications where hazardous fumes or dust may be present.
Specification # 35-0000-0881
Specs
Catalog NumberCXM05122
EnclosureTEFC
Frame56C
Frame MaterialSteel
Frequency50.00 Hz
60.00 Hz Haz Area Class and GroupCLI GP D; CLII GP F,G Haz Area DivisionDivision I Motor Letter TypeThree Phase Output @ Frequency1.000 HP @ 60 HZ
.750 HP @ 50 HZ Phase3 Synchronous Speed @ Frequency3600 RPM @ 60 HZ Voltage @ Frequency380.0 V @ 50 HZ
230.0 V @ 60 HZ
460.0 V @ 60 HZ
190.0 V @ 50 HZ Agency ApprovalsUL
CSA EEV Ambient Temperature40 °C Auxillary BoxNo Auxillary Box Auxillary Box Lead TerminationNone Base IndicatorRigid Bearing Grease TypePolyrex EM (-20F +300F) BlowerNone Constant Torque Speed Range6 Current @ Voltage2.800 A @ 230.0 V
2.600 A @ 190.0 V
1.400 A @ 460.0 V
1.300 A @ 380.0 V Design CodeB Drip CoverNo Drip Cover Duty RatingCONT Efficiency @ 100% Load82.5 % Electrically Isolated BearingNot Electrically Isolated Feedback DeviceNO FEEDBACK Haz Area Temp CodeT3C Heater IndicatorNo Heater High Voltage Full Load Amps1.3 a Insulation ClassF Inverter CodeInverter Duty IP RatingNONE KVA CodeL Lifting LugsNo Lifting Lugs Locked Bearing IndicatorLocked Bearing Max Speed5400 rpm Motor Lead TerminationFlying Leads Motor StandardsNEMA Motor Type3516M Mounting ArrangementF1 Number of Poles2 Overall Length14.28 IN Power Factor82 Product FamilyGeneral Purpose Pulley Face CodeC-Face Rodent ScreenNone RoHS StatusROHS NON-COMPLIANT Service Factor1.00 Shaft Diameter0.625 IN Shaft Ground IndicatorNo Shaft Grounding Shaft RotationReversible Speed3450 rpm Speed CodeSingle Speed Starting MethodDirect on line Thermal Device - BearingNone Thermal Device - WindingNormally Closed Thermostat Vibration Sensor IndicatorNo Vibration Sensor Winding Thermal 1None Winding Thermal 2None
60.00 Hz Haz Area Class and GroupCLI GP D; CLII GP F,G Haz Area DivisionDivision I Motor Letter TypeThree Phase Output @ Frequency1.000 HP @ 60 HZ
.750 HP @ 50 HZ Phase3 Synchronous Speed @ Frequency3600 RPM @ 60 HZ Voltage @ Frequency380.0 V @ 50 HZ
230.0 V @ 60 HZ
460.0 V @ 60 HZ
190.0 V @ 50 HZ Agency ApprovalsUL
CSA EEV Ambient Temperature40 °C Auxillary BoxNo Auxillary Box Auxillary Box Lead TerminationNone Base IndicatorRigid Bearing Grease TypePolyrex EM (-20F +300F) BlowerNone Constant Torque Speed Range6 Current @ Voltage2.800 A @ 230.0 V
2.600 A @ 190.0 V
1.400 A @ 460.0 V
1.300 A @ 380.0 V Design CodeB Drip CoverNo Drip Cover Duty RatingCONT Efficiency @ 100% Load82.5 % Electrically Isolated BearingNot Electrically Isolated Feedback DeviceNO FEEDBACK Haz Area Temp CodeT3C Heater IndicatorNo Heater High Voltage Full Load Amps1.3 a Insulation ClassF Inverter CodeInverter Duty IP RatingNONE KVA CodeL Lifting LugsNo Lifting Lugs Locked Bearing IndicatorLocked Bearing Max Speed5400 rpm Motor Lead TerminationFlying Leads Motor StandardsNEMA Motor Type3516M Mounting ArrangementF1 Number of Poles2 Overall Length14.28 IN Power Factor82 Product FamilyGeneral Purpose Pulley Face CodeC-Face Rodent ScreenNone RoHS StatusROHS NON-COMPLIANT Service Factor1.00 Shaft Diameter0.625 IN Shaft Ground IndicatorNo Shaft Grounding Shaft RotationReversible Speed3450 rpm Speed CodeSingle Speed Starting MethodDirect on line Thermal Device - BearingNone Thermal Device - WindingNormally Closed Thermostat Vibration Sensor IndicatorNo Vibration Sensor Winding Thermal 1None Winding Thermal 2None
Nameplate
| NO. | CC | 010A | |||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| S/N | TEMP CODE | T3C | |||||||||||||||||||||||||||||||||||||||||||||||||||||
| SPEC. | 35-0000-0881 | INV.TYPE | PWM | ||||||||||||||||||||||||||||||||||||||||||||||||||||
| CAT.NO. | CXM05122 | C HP FR | 60 | C HP TO | 90 | ||||||||||||||||||||||||||||||||||||||||||||||||||
| HP | 1//0.75 | CT HZ FROM | 6 | CT HZ TO | 60 | ||||||||||||||||||||||||||||||||||||||||||||||||||
| VOLTS | 230/460//190/380 | VT HZ FROM | 6 | VT HZ TO | 60 | ||||||||||||||||||||||||||||||||||||||||||||||||||
| AMPS | 2.8/1.4//2.6/1.3 | MAG CUR | .67 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
| RPM | 3450//2885 | MX RPM | 5400 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
| HZ | 60//50 | PH | 3 | CL | F | NOM.EFF. | 82.5 | ||||||||||||||||||||||||||||||||||||||||||||||||
| SER.F. | 1.00 | DES | B | SL HZ | 2.5 | WK2 | 0.05 | ||||||||||||||||||||||||||||||||||||||||||||||||
| FRAME | 56C | RATING | 40C AMB-CONT | ||||||||||||||||||||||||||||||||||||||||||||||||||||
| NEMA MG-1 PART 5, IP54 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 1.15 SF ON SINE WAVE | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
| NP0887XPSLEV | |||||||||||||||||||||||||||||||||||||||||||||||||||||||